profile-img

Manoj Kumar

Quality Manager at STRABAG AG AFCONS JOINT VENTURE

Jalandhar, India

Work Experience

  • Quality ManagerFull Time

    STRABAG AG AFCONS JOINT VENTURE

    Dec 2019 - Present -5 yrs, 7 months

    India , Shimla

    • Job Details:Involve in making ITP, QAP, setup of laboratories, Internal Audits, source approvals of all type of construction materials. Mix design of all type of concrete grades as per technical specification; M50 PQC Concrete as per MoRTH, Special Concrete S35 for Tunnel Lining Concrete (Additives; 18 micron PP Fibre & Micro Silica 920D), M40 A20 for Precast structures and Ventilation Duct Slab, M15 A10 & M15 A20 grade of concrete for PCC works, Grout Mix Design, Technical Backfill Job Mix Formula design for backfill purpose and it’s testing Maximum Dry Density and Field Dry Density, SFRS C40 A10 & Macro PP Fibre Barchip54 for C35 A10, Tunneling by NATM, Field Tests to ensure the quality of work at site, Aggregate testing; Crushing value, Impact Value, Los Angeles Abrasion Value Test, Micro Devel Test, Density Test, Specific Gravity and Water Absorption Test, GSA etc., Third party joint sampling of all construction material, Involve in geological investigations at the time of SERI Nala Fault Zone, we handled Seri Nala fault zone with Pipe Roofing Methodology (114.3mm dia, 88.9mm & 76.0mm perforated pipes with Cement Grout), Use of PU Grout - Polyurethane Grouts (Component A & B type), plate load test also conducted at site for the foundation of control building, Pullout Test for rock bolts – Swellex, IBO’s, SDA etc., Also involve in testing of cable anchors at portal building, test on PQC concrete; Texture depth, rebound hammer test, core strength test, beam test, Road Marking; test on drop on type glass beads at site, thickness of thermoplastic paint, use of Digital Refractrometer to test the Cat Eye, Delineators and Thermoplastic paint with glass beads refraction quality etc., Maintain and update all the documentation and on time submissions of all test reports.
  • Quality ManagerFull Time

    TEXMACO RAIL AND ENGINEERING LIMITED

    Nov 2018 - Dec 2019 -1 yr, 1 month

    Bangladesh

    • Job Details:Involve in making ITP, QAP, setup of laboratories, Internal Audits, source approvals of all type of construction materials. OGL Sampling, SPT Sampling, Borrow Area Soil Investigation for suitability test of soil; (NMC) Natural Moisture Content, (GSA) Grain size analysis of Soil, Sand content, Liquid Limit, Plastic Limit, Plasticity Index, Soil type as per IS 1498, Soil Type as per RDSO, Lab MDD, OMC, CBR test, involve in design the thickness of sub-grade and blanket for 25 T Axle Load / 32.5 T Axle Load in single layer/ two layer as per RDSO guidelines, Design of blanket material by using suitable material at optimized level of quality control, Testing of Ballast Material for railway track, EV2 Test for check the behavior of each bedding layer of subsoil/sub grade/prepared sub grade/blanket layer etc. to check the bearing capacity of soil as well as deformation conditions, Geotechnical measures to control the water seepage by using PVD (Perforated Vertical Drains system) and it’s monitoring by Piezometers, Inclinometer etc. Concrete mix design for Pile foundations, Bridges and Culverts (M50, M40, M35, M30, M25, M20 and M15), All aggregate testing as per IS 2386; Crushing value, Impact Value, Los Angeles Abrasion Value Test, Micro Devel Test, Density Test, Specific Gravity and Water Absorption Test, GSA etc., Maintain and update all the documentation and on time submissions of all test reports.
  • Manager QAQCFull Time

    Afcons Infrastructure Limited

    Apr 2011 - Nov 2018 -7 yrs, 7 months

    India , Shimla

    • Job Details:Involve in making ITP, QAP, setup of laboratories, Internal Audits, source approvals of all type of construction materials. Mix design of all type of concrete grades as per technical specification; M50 PQC Concrete as per MoRTH, Special Concrete S35 for Tunnel Lining Concrete (Additives; 18 micron PP Fibre & Micro Silica 920D), M40 A20 for Precast structures and Ventilation Duct Slab, M15 A10 & M15 A20 grade of concrete for PCC works, Grout Mix Design, Technical Backfill Job Mix Formula design for backfill purpose and it’s testing Maximum Dry Density and Field Dry Density, SFRS C40 A10 & Macro PP Fibre Barchip54 for C35 A10, Tunneling by NATM, Field Tests to ensure the quality of work at site, Aggregate testing; Crushing value, Impact Value, Los Angeles Abrasion Value Test, Micro Devel Test, Density Test, Specific Gravity and Water Absorption Test, GSA etc., Third party joint sampling of all construction material, Involve in geological investigations at the time of SERI Nala Fault Zone, we handled Seri Nala fault zone with Pipe Roofing Methodology (114.3mm dia, 88.9mm & 76.0mm perforated pipes with Cement Grout), Use of PU Grout - Polyurethane Grouts (Component A & B type), plate load test also conducted at site for the foundation of control building, Pullout Test for rock bolts – Swellex, IBO’s, SDA etc., Also involve in testing of cable anchors at portal building, test on PQC concrete; Texture depth, rebound hammer test, core strength test, beam test, Road Marking; test on drop on type glass beads at site, thickness of thermoplastic paint, use of Digital Refractrometer to test the Cat Eye, Delineators and Thermoplastic paint with glass beads refraction quality etc., Maintain and update all the documentation and on time submissions of all test reports.
  • senior engineer qualityFull Time

    Afcons Infrastructure Limited

    May 2010 - Apr 2011 -11 months

    India , Shimla

    • Job Details:Involve in making ITP, QAP, setup of laboratories, Internal Audits, source approvals of all type of construction materials. Mix design of all type of concrete grades as per technical specification; M50 PQC Concrete as per MoRTH, Special Concrete S35 for Tunnel Lining Concrete (Additives; 18 micron PP Fibre & Micro Silica 920D), M40 A20 for Precast structures and Ventilation Duct Slab, M15 A10 & M15 A20 grade of concrete for PCC works, Grout Mix Design, Technical Backfill Job Mix Formula design for backfill purpose and it’s testing Maximum Dry Density and Field Dry Density, SFRS C40 A10 & Macro PP Fibre Barchip54 for C35 A10, Tunneling by NATM, Field Tests to ensure the quality of work at site, Aggregate testing; Crushing value, Impact Value, Los Angeles Abrasion Value Test, Micro Devel Test, Density Test, Specific Gravity and Water Absorption Test, GSA etc., Third party joint sampling of all construction material, Involve in geological investigations at the time of SERI Nala Fault Zone, we handled Seri Nala fault zone with Pipe Roofing Methodology (114.3mm dia, 88.9mm & 76.0mm perforated pipes with Cement Grout), Use of PU Grout - Polyurethane Grouts (Component A & B type), plate load test also conducted at site for the foundation of control building, Pullout Test for rock bolts – Swellex, IBO’s, SDA etc., Also involve in testing of cable anchors at portal building, test on PQC concrete; Texture depth, rebound hammer test, core strength test, beam test, Road Marking; test on drop on type glass beads at site, thickness of thermoplastic paint, use of Digital Refractrometer to test the Cat Eye, Delineators and Thermoplastic paint with glass beads refraction quality etc., Maintain and update all the documentation and on time submissions of all test reports.
  • Education

    • Bachelor's Degree in Civil engineering

      PUNJAB technical University, Jalandhar

      Jan 2005 

    • Technical Diploma in Civil Engineering

      Punjab State Board of Technical Education and Industrial Training Mohali

      Jan 1998 - Jan 2001 - 3 yr

    • High School - Other

      Punjab School Education Board Mohali

      Jan 1996 

    Achievements

    World's longest tunnel at high altitude of above 10000 feet successfully completed ATAL Tunnel Rohtang Project.

    Skills

    • Photography
    • Driving
    • Internet
    • Microsoft Office

    Languages

    • English

      Advanced
    • Hindi

      Advanced
    • Punjabi

      Advanced
    Share this Profile